Cryogenic refrigerator
OpenI-Liquefier40 Compact Movable Helium Liquefier has a typical feature that the cold head inserts into the Dewar directly. The Helium compressor and the liquefier is integrated together and be skid-mounted into a small dimension, which is movable in the state of power-on. The liquid helium can be transferred into the customer’s device directly, no need a transportation Dewar so that the liquid helium consumption is avoided.
Helium liquefy rate | 40L/d |
Dimension | 1650x760x1735mm (compressor included) |
Weight | 480kg |
Cold head | KDE415SA |
compressor | KDC6000V |
Quantity of cryocooler | 2 sets |
Dewar | 200L |
Cooling time | <4h |
Power supply of GM cryocooler | 3PH AC380V 50Hz |
Cooling down: 14.4Kw | |
Operation: 13Kw | |
Power supply of control unit | Single PH AC110V—240V 50~60Hz (Power consumption<1KW) |
Cooling water | Inlet temperature 5~25℃, flow rate7-9L/min, pressure<8bar |
Helium requirement | Purity: >99.999% |
Inlet Temp.: -20℃~40℃ | |
Helium requirement | Purity: >99.999% |
Inlet Temp.: -20℃~40℃ |
CSIC Pride(Nanjing)Cryogenic Technology Co., Ltd.